Diameters / Packaging
DETAILS
LincoreĀ® 55 Flux-Cored Wire delivers a deposit which resists metal-to-metal rolling or sliding wear as well as mild abrasion. Composition and properties depend upon dilution. Single layer deposit properties depend upon base metal and/or build-up material. Cold parts should be warmed to at least 25ĀŗC (75ĀŗF). Higher preheat of 150 - 260ĀŗC (300 - 500ĀŗF) may be necessary on thick parts or heavy sections. Interpass temperature between 150ĀŗC (300ĀŗF) and 200ĀŗC (400ĀŗF) do not affect the hardness of LincoreĀ® 55 significantly.
Features
- Delivers a deposit which resists metal-to-metal rolling or sliding wear as well as mild abrasion
- To be used on carbon steel, low alloy steel and manganese steel
- Unlimited layers with proper preheat and interpass temperatures and procedures
Disclaimers
Service Information
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
MECHANICAL PROPERTIES
Classification | Number of layer | Hardness Rockwell C |
---|---|---|
Typical Result | 1 Layer | 50-59 |
Typical Result | 2 Layers | 50-60 |
Typical Result, Work-hardened | 1 Layer | 53-62 |
Typical Result, Work-hardened | 2 Layers | 56-62 |
Typical Result, Flame-hardened | 2 Layers | 52-54 |
Typical Result, 180°C (350°F) Interpass Temp | 1 Layer | 50-55 |
Typical Result, 180°C (350°F) Interpass Temp | 2 Layers | 55-59 |
DEPOSIT COMPOSITION
Classification | Product Size | %Al | %C | %Cr | %Mn | %Mo | %P | %S | %Si |
---|---|---|---|---|---|---|---|---|---|
Typical Result | .045" (1.1 mm) | 1.4 | 0.45 | 5.3 | 1.3 | 0.8 | 0.010 | 0.004 | 0.53 |
Typical Result | 1/16" (1.6 mm) | 1.4 | 0.45 | 5.3 | 1.3 | 0.8 | 0.010 | 0.004 | 0.53 |
Typical Result | 5/64" (2.0 mm) | 1.4 | 0.45 | 5.3 | 1.4 | 0.8 | 0.010 | 0.004 | 0.60 |
Typical Result | 7/64" (2.8 mm) | 1.4 | 0.45 | 5.3 | 1.4 | 0.8 | 0.010 | 0.004 | 0.60 |
TYPICAL OPERATING PROCEDURES
Diameter | Polarity |
ESO
mm (in.) |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Deposition Rate
kg/hr (lb/hr) |
---|---|---|---|---|---|---|
0.045 in (1.1 mm) | DC+ | 45 (1 3/4) | 5.1 (200) | 25 | 85 | 1.6 (3.6) |
0.045 in (1.1 mm) | DC+ | 45 (1 3/4) | 8.9 (350) | 28 | 125 | 3.0 (6.6) |
0.045 in (1.1 mm) | DC+ | 45 (1 3/4) | 12.7 (500) | 31 | 165 | 4.3 (9.4) |
1/16 in (1.6 mm) | DC+ | 45 (1 3/4) | 3.8 (150) | 26 | 125 | 2.2 (4.8) |
1/16 in (1.6 mm) | DC+ | 45 (1 3/4) | 6.4 (250) | 29 | 195 | 3.8 (8.4) |
1/16 in (1.6 mm) | DC+ | 45 (1 3/4) | 8.9 (350) | 32 | 245 | 5.5 (12.1) |
5/64 in (2.0 mm) | DC+ | 45 (1 3/4) | 3.2 (125) | 24 | 190 | 3.2 (7.0) |
5/64 in (2.0 mm) | DC+ | 45 (1 3/4) | 5.1 (200) | 27 | 295 | 5.0 (11.0) |
5/64 in (2.0 mm) | DC+ | 45 (1 3/4) | 6.4 (250) | 30 | 330 | 6.2 (13.7) |
7/64 in (2.8 mm) | DC+ | 64 (2 1/2) | 2.3 (90) | 25 | 280 | 3.8 (8.4) |
7/64 in (2.8 mm) | DC+ | 64 (2 1/2) | 3.2 (125) | 27 | 350 | 5.2 (11.5) |
7/64 in (2.8 mm) | DC+ | 64 (2 1/2) | 4.4 (175) | 30 | 420 | 7.3 (16.0) |
NOTES
Note |
---|
Cold parts should be warmed to at least 25°C (75°F). Higher preheat of 150 - 260°C (300 - 500°F) may be necessary on thick parts or heavy sections. |
Interpass temperatures between 150°C (300°F) and 200°C (400°F) do not affect the hardness of Lincore® 55 significantly. |