10 Pound Cans of Stick Electrode

Diameters / Packaging

Diameters
(3) 10 lb Easy Open Can
50 lb Easy Open Can
2.5 x 350 mm (3/32 x 14 in) ED033835
2.5 x 355 mm (3/32 x 14 in) ED030916
3.2 x 350 mm (1/8 x 14 in) ED033836
3.2 x 355 mm (1/8 x 14 in) ED030917
4.0 x 450 mm (5/32 x 18 in) ED030918

Pipeliner® 16P

Stick (SMAW)

CLASSIFICATIONS:
E7016-H4
E7016-1 H4

Mild Steel, Low Hydrogen • AWS E7016-1 H4

DETAILS

Designed for root pass welding of up to X100 grade pipe

Features

  • DC- (DCEN) is the recommended polarity for root pass welding on pipe

Typical Applications

  • Root pass welding
  • Hot, fill and cap pass welding up to X60
  • Low hydrogen, vertical up capability on X60 grade pipe

Welding Positions

  • All position, except vertical down

Shielding Gas

  • Not Applicable

Special Features

  • Q2 Lot® - Lot Controlled Chemistry and Mechanical Properties

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

You May Also Need

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.1 E7016-1 H4, E7016-H4
ABS AWS A5.1 E7016-H4
CWB AWS A5.1 E4916-H4

MECHANICAL PROPERTIES

Classification Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F)
Charpy V-Notch
J (ft-lbs) @ -45°C (-50°F)
E7016-1 H4 Requirement 400 (58) min. 480 (70) min. 22 min. 27 (20) min.
Typical Result, As-welded 420-550 (61-79) 510-640 (74-93) 25-41 27-186 (20-137) 29-168 (22-124)

DEPOSIT COMPOSITION

Classification %C %Cr %Mn %Mo %Ni %P %S %Si %V %Mn+Ni+Cr+Mo+V Diffusible Hydrogen
mL/100g Weld Metal
1800F H2O - As received
E7016-1 H4 Requirement 0.15 max. 0.20 max. 1.60 max. 0.30 max. 0.30 max. 0.035 max. 0.035 max. 0.75 max. 0.08 max. 1.75 max. 4 max. 0.6 max.
Typical Result 0.04-0.08 0.02-0.05 1.03-1.47 0.02 max. 0.01-0.04 0.008-0.014 0.003-0.012 0.32-0.57 0.02 max. 1.09-1.48 1-4 0.3 max.

TYPICAL OPERATING PROCEDURES

Diameter Polarity⁽¹⁾ Current
Amps
2.5 mm (3/32 in) DC± 55-105
2.5 mm (3/32 in) AC 60-115
3.2 mm (1/8 in) DC± 75-135
3.2 mm (1/8 in) AC 80-150
4.0 mm (5/32 in) DC± 120-170
4.0 mm (5/32 in) AC 120-185

NOTES

Note
⁽¹⁾ Preferred polarity is listed first.
DC- for root pass on pipe; DC± for general welding