Blue Max Stainless Wire

Diameters / Packaging

Diameters
33 lb (15 kg) Steel Spool
0.035 in (0.9 mm) MG825035667
0.045 in (1.1 mm) MG825045667
1/16 in (1.6 mm) MG825062667

Techalloy® 825

MIG (GMAW)

CLASSIFICATIONS:
AWS ERNiFeCr-1

TECHALLOY® 825 Metal Inert Gas Wire designed for MIG and TIG welding of nickel-chromium-molybdenum-copper alloy (ASTM B 423 having UNS number N08825) to itself.

DETAILS

TECHALLOY® 825 is ideal for welding the nickel-chromium-molybdenum-copper alloys. This alloy can be used for overlay cladding where similar chemical composition is required.

Features

  • Used for MIG and TIG welding of nickel-chromium-molybdenum-copper alloys
  • Can be used to overlay cladding where similar chemical composition is required
  • Q2 Lot® - Certificate showing actual wire composition available online

Typical Applications

  • Used for welding the nickel-iron-chromium-molybdenum-copper alloy (ASTM B 423 having UNS number N08825) to itself
  • General Fabrication
  • Maintenance and Repair

Welding Positions

  • All

Shielding Gas

  • MIG 75% Argon / 25% Helium

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.14 ERNiFeCr-1
ABS AWS A5.14 ERNiFeCr-1
CWB AWS A5.14 ERNiFeCr-1

WIRE COMPOSITION

Classification %Al %C %Cr %Cu %Fe %Mn %Mo %P %S %Si %Ti %Ni+Co
ERNiFeCr-1 Requirement 0.20 max. 0.05 max. 19.5 - 23.5 1.5 - 3.0 22.0 min. 1.0 max. 2.5 - 3.5 0.03 max. 0.03 max. 0.50 max. 0.6 - 1.2 38.0 - 46.0
Typical Result 0.05 0.01 22.9 2.5 25.2 0.6 3.1 0.01 0.003 max. 0.15 1.1 44.3

TYPICAL OPERATING PROCEDURES

Diameter Shielding Gas Polarity Voltage
volts
Approx. Current
amps
.035" (0.9 mm) 75% Ar, 25% He DC+ 26-29 150-190
.045" (1.1 mm) 75% Ar, 25% He DC+ 28-32 180-220
1/16" (1.6 mm) 75% Ar, 25% He DC+ 29-33 200-250