Submerged Arc Family

Diameters / Packaging

Diameters
55 lb Spool
1/8 in (3.2 mm) ED035188

Lincolnweld® 410NiMo

Submerged Arc Welding (SAW)

CLASSIFICATIONS:
AWS A5.9 : ER410NiMo

Used to overlay mild and low alloy steels

DETAILS

Lincoln Electric's combination of submerged arc wire and flux is designed to produce sizeable weld deposits with exceptional quality and bead appearance

Features

  • Used to overlay mild and low alloy steels
  • Preheat and inter-pass temperatures of 300°F (150°C) or greater are recommended during welding
  • Post-weld heat treatment should not exceed 1150°F (620°C) as higher temperatures may result in hardening

Typical Applications

  • Power Generation
  • Turbines
  • Power Plants

Welding Positions

  • No es aplicable

Shielding Gas

  • N/A

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.9 ER410NiMo

WIRE COMPOSITION

Classification %C %Cr %Cu %Mn %Mo %N %Nb %Ni %P %S %Si
ER410NiMo Requirement 0.06 max. 11.0 - 12.5 0.75 max. 0.6 max. 0.4 - 0.7 Info. Only Info. Only 4.0 - 5.0 0.03 max. 0.03 max. 0.5 max.
Typical Result 0.02-0.03 11.8-12.1 0.04-0.06 0.4-0.5 0.5-0.6 0.02-0.05 0.00 max. 4.5-4.7 0.01-0.02 0.01 max. 0.4

TYPICAL OPERATING PROCEDURES

Diameter Voltage
volts
Approx. Current
amps
Flux
1/8 in (3.2 mm) 29-32 350-450 Lincolnweld® P2000™