Hardfacing Consumables Family Group

Diameters / Packaging

Diameters
25 lb (11.3 kg) Coil
5/64 in (2.0 mm) ED035628

Lincore® TiCore

Flux-Cored Self-Shielded (FCAW-S)

LINCORE® TiCore Flux-Cored Wire ideal for build-up of tool steel dies and edges or applying wear resistance on metal-to-metal carbon, low alloy and tool steel (Severe Abrasion)

Détails

LINCORE® TiCore Flux-Cored Wire for better wear characteristics than martensitic only deposit, Low spatter and easy slag cleanup. Typical application on Wear plate, Crusher rolls and Ore Chutes. Limited to 4 layers max. Composition and properties depend upon dilution. Single layer deposit properties depend upon base metal and/or build-up material.

Traits

  • Better wear characteristics than martensitic only deposit
  • Low spatter and easy slag cleanup
  • Deposits do not check crack
  • Limited to 4 layers max

Applications typiques

  • Wear plate
  • Crusher rolls
  • Ore Chutes

Positions de soudage

  • Flat/Horizontal

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

MECHANICAL PROPERTIES

Classification Hardness Rockwell C Mass Loss (G65)
Typical Result 52-60 0.27

DEPOSIT COMPOSITION

Classification Number of layer %C %Cr %Mn %Mo %Si %Ti %V
Typical Result 4 Layers 2.5 8.5 1.3 1.9 1.5 8.6 0.4

TYPICAL OPERATING PROCEDURES

Diameter Polarity ESO
mm (in.)
Wire Feed Speed
m/min (in/min)
Voltage
volts
Approx. Current
amps
5/64 in (2.0 mm) DC+ 38 (1 1/2) 5.1 (200) 27 260