Diameters / Packaging
Diameters |
---|
DETAILS
The highest strength MIG wire in the Pipeliner® family. Recommended for root pass welding of up to X100 grade pipe as well as hot, fill and cap pass welding of up to X80 grade pipe.
Features
- Root pass capability up to X100 and hot, fill and cap pass up to X80 grade pipe
- Microguard® Ultra provides superior feeding and arc stability
- Impact toughness tested to -29°C (-20°F)
- Q2 Lot® - Certificate showing actual deposit chemistry available online
- ProTech® packaging system
Typical Applications
- Root pass welding of up to X100 grade pipe
- Hot, fill and cap pass welding of up to X80 grade pipe
Welding Positions
- All
Shielding Gas
- 100% CO2|Mixed Shielding Gas
Disclaimers
Service Information
Documentation
You May Also Need
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.28 | ER80S-G |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
Hardness Rockwell B |
---|---|---|---|---|---|---|---|
ER80S-G Requirement | Not Specified | DC+ | 550 (80) min. | Info. Only | |||
Typical Result, As-welded | 100% CO2 | DC+ | 630 (91) | 700 (101) | 25 | 70-87 (52-64) | 97 |
Typical Result, As-welded | 75% Ar, 25% CO2 | DC+ | 650 (94) | 720 (104) | 17 | 103-111 (76-82) | |
Typical Result, As-welded | 80% Ar, 20% CO2 | DC+ | 610-650 (88-94) | 690-730 (100-106) | 23-26 | 73-183 (54-135) |
DEPOSIT COMPOSITION
Classification | Shielding Gas | Polarity | %C | %Cr | %Cu | %Mn | %Mo | %Ni | %P | %S | %Si |
---|---|---|---|---|---|---|---|---|---|---|---|
Typical Result | 100% CO2 | DC+ | 0.09 | 0.05 | 0.18 | 1.39 | 0.40 | 0.04 | 0.008 | 0.006 | 0.40 |
Typical Result | 75% Ar, 25% CO2 | DC+ | 0.10 | 0.05 | 0.17 | 1.42 | 0.45 | 0.01 | 0.01 | 0.48 |
WIRE COMPOSITION
Classification | %Al | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %Ti | %V | %Zr | %Total Cu |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ER80S-G Requirement | 0.30 min. * | 0.20 min. * | 0.50 min. * | ||||||||||
Typical Result | 0.00 max. | 0.09-0.10 | 0.02-0.03 | 1.73-1.81 | 0.45-0.47 | 0.01-0.02 | 0.006-0.008 | 0.003-0.009 | 0.61-0.64 | 0.01-0.03 | 0.00 max. | 0.00 max. | 0.15-0.28 |
TYPICAL OPERATING PROCEDURES
Diameter | Polarity |
CTWD
mm (in.)⁽¹⁾ |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Melt-off Rate
kg/hr (lb/hr) |
---|---|---|---|---|---|---|
1.1 mm (0.045 in) | DC+ | 12-19 (1/2-3/4) | 3.2-12.7 (125-500) | 19-30 | 145-340 | 1.5-6.0 (3.4-13.2) |
NOTES
Note |
---|
* To meet the requirements of a "G" classification, the chemical composition of the eletrode must meet the minimum requirement for one or more of |
⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in (6.4 mm) to calculate Electrical Stickout. |